,,•Si,yy r1RDINANCE PROVIDING FOR THE LICENSING OF PLUMBERS, PERMITS, INSPECTIONS, GENERAL REGUL- ATIONS CONCERNING QUALITY AND WCIGIIT OF MATERIALS, AND GENERAL REGULATIONS CONCERNING THE ,:..INSTALLATION OF FIXTURES, DRAINS, ETC. I, 'CTION L. DEFINITIONS. The purpose of this Ordinance and certain words and phrases herein are defined as follows. A. BUILDING: An architectural structure covered by one roof having closed walls with doors and windows therein. B. PRIVATE DWELLING: A dwelling house detached from any other building, designed for the use of one family only and having not to exceed one kitchen and one meter for measuring electric current. C. RURAL AND ISOLATED RESIDENCES: Those situated at such distance from a public sewer system that their drainage cannoL became a tributary thereto. ilc D. PLUMBING SYSTEM: The water distribution pipes, fixtures, and fixture traps, soil, waste i. and vent pipes, house drain and house sewer and storm water drainage with their appuretenances 4 and connections all within or adjoining to the building. E. PLUMBING FIXTURES: Receptacles intended to receive and discharge water, liquid, or water carried waste into a drainage system with which they are connected. F. SANITARY PLUMBING: Plumbing that .is free from defects in construction, conforms in every j particular to the provisions of this Ordinance and is so designed and installed that it can be kept clean. WATER SERVICE PIPES: The pipe from the water main to the building served. H. STORM WATER DRAIN: Any pipe or drain which receives any discharge of rain water from buildings or premises, or any seepage or ground water and conveys the same to any public sewer, building sewer, or water course. I. WATER DISTRIBUTION PIPES: Those which convey water from the service pipe to the plumbing fixture. J. .VENT PIPE: Any pipe provided to ventilate a building drainage system and to prevent trap siphonage and back pressure. K. CONTINUOUS VENT: .A pipe extending vertically above the soil or waste branch. L. CIRCUIT VENT: A pipe which vents a series of fixture traps on the same soil or water branch and which is continued through the roof or reconnected into a vent static above all fixture trap branches. M. UNIT VENT: A pipe so arranged that it will vent two traps. N. RETURN VENT: An inverted emergency vent extended above the water line of the fixture and returned to a point of connection with the horizontal runof the waste pipe from the fix- ture served on the sewer side of the branch waste from the fixture. 0. WASTE VENT: That part of a stach which extends above the highest installed fixture trap - nther than a water closet. SOIL VENT: A part of a stack which extends above the highest installed water closet. Q. STACK VENT: A pipe connecting to the'side inlet of a fitting venting a water closet R. WET VENT: A pipe used to vent a trap which is also used as a waste pipe from another trap. 0 v.. :1 .diviauN . trap, undo. acl ue u:. 6, vent pipe. ..T. LOCAL VENT: A pipe Lhrough which foul air is removed from a roan or the hou:;� side of a fixture. f `` .,U.. SEWAGE: Any ]. _d wa:;t:e containing anim l or vegetable waste in sus�)ension or aolut5 May include liquids from laboratories or industrial institutions containing minerals. in solution. V. HOUSE SEWER: That part of a horizontal piping of a drainage system extending from the; house drain to its connection with the main sewer, sewage treatment tank or leaching well: W. SANITARY SEWER: A drain or sewer constructed to convey organic sewage from buildings. in a septic tank or bacterial treatment tank or other point of disposal, and from which'all surface and storm water is excluded. vs: - SEPTIC "- SEPTIC OR SEWAGE TREATMENT TANK: A water tight receptacle so constructed as to promote the separation and decomposition of raw sewage which, by bacterial action and sedimentation, effects a paocess of clarification but does not purify the effluent. C Y. LEACHING WELL OR CESSPOOL: Any pit or receptacle having porous walls which permit he= epage into the ground. Z. TRAP: A fitting or device so constructed as to -prevent the passage of air or gas,the& ough it without materially affecting the flow of sewage or wa4te water through it. AA. TRAP SEAL: The vertical distance between the crown weir)and the depth of the trap. BB. THE DURHAM SYSTEM: The Durham system of plumbing is an installation of waste and'80il pipes constructed of brass, copper, wrought iron, steel, or cast iron pipes joined.toget• by means of threaded drainage fittings. CC. LEAD AND SOIL SYSTEM: A lead and soil system of plumbing is an installation of'soil and waste pipes constructed of lead and cast iron soil pipes joined together by means Cf'•" - wiped and caulked joints. DD. SUBSOIL DRAIN: That part of a drainage system which conveys the subsoil, ground or .seepage water from the foot walls or from below the cellar bottom under buildings to the building drain, storm water drain, or.building sewer. EE. WASTE PIPE. Any pipe which receives the discharge of any fixture, except water clo- sets. amd cpmveus tje sa,e tp tje jpise draom. spot. pr waste stacls/ Iden such a pipe does not connect directly with a house drain or soil stack itIis termed a special waste. FF. SOIL PIPE: Any pipe which conveys the discharge of wateb closets with or without the discharge from other fixtures. GG. HOUSE DRAIN: any system of horizontal, vertical, or continous piping which receives the wastes from fixtures, outlets, or traps directly.or through branch pipes. HH. BRANCH: The branch of any system of piping is the part of the system which extends horizontally at a slight grade, with or'withdut lateral or vertical extensions or vertical arms, from the house drain to receive fixture outlets not directly connected to the•house drain. II. STACK: A general term for any vertical line of soil, waste'or vent piping. JJ. CONDUCTOR: Pipe which carries the storm or rain water from the roof of a building to the building sewer or storm water drain. Down spout is the term which is frequently.used. to denote the vertical portion of a conductor or roof ladder. KK. DEAD END: A branch leading from a soil, vent waste building sewer, which is terminated "i used for admitting water to the pipe. LL. SIZE AND LENGT11. The given calibre of size of a pipe is for a nominal internal,diameter. ,-The developed length of a pipe is its length along the center line of pipe and fittings,, *I. WIPING A JOINT: A method of joining together two pieces of metal, to which solder iu t; applied on the jodnt to a uniforhp heat sufficient to obtain a smooth, neatly wiped finish, over the part of the joint where the metal joins. SECTION 2. PERMIT REQUIRED. With the exception of repairing leaks, cocks, or valves, or cleaning waste or sewer pipes,,no person firm or corporation, or owner shall construct, install alter, or remodel any plumbipz or drainage on or for any building in the Town without securing in advance from'the Build#ng Inspector a permit therefore. SECTION 3. PERMIT AND REINSPECTION FEES. There shall be no charges by the Building Inspector for permits covering the installation'of any plumbin, the laying of any drain, or the tapping of a sewer or water line; and there.. shall be no charge made for any reinspection necessary. SECTION 4 INSPECTION. . A. All plumbing and steam fitting installation and connections therewith shall be subject to inspection by the Building Inspector who shall ascertain any and'all violations of this Ordinance. B. The equipment, material and labor necessary for inspection and test shall be furnished, by the permittee. All work installed shall be tested in the rough with a water and air test, and all joints shall be made tight. In cases where inspection in,the rough is not feasible within eight working hours after request for inspection is received the Building Inspector shall no jfy, the plumber to proceed with the work. If, upon inspection.the•character of the work.is.such as to cause a reasonable doubt as to its tightness it shall be subject to a test,upon.the direction of the Building Inspector. D. If inspection or test of plumbing reveals improper installation or defects in material, such defective material or improper installation shall be'replaced, altered, or repaired, not later than a date specified in writing on a tag or label attached to the system iri.a conspicuous place by the Building Inspector. E. Upon the satisfactory completion and final inspection of the plumbin, a tag or label ,of approval shall be attached to the system in a conspicuous place certifying that the plumbing has met the requirements of the Building Inspector. F. No permit or test shall be required for the repair of an old fixture after forcing out stoppage or repairing a leak. . ' SECTION 5. SEPERATE DITCHES FOR SERVICE PIPES. No water or other service pipe shall be placed in -the same ditch with a gas service pipe unless such water or other service pipe be placed not less than twelve inches horizontally from the gas pipe. TION 6. GENERAL REGULATIONS A.' All horizontal sewer piping shall be run at a uniform grade of not less than one-eighth, of an inch per foot, and shall be supported or anchored at intervals of not to exceed ten feet. All stacks shall be supported at their base and all pipes shall be rigidly secured. ,cks shall u� .;V ulr �.• . ....i �tt,cs .,/ ::��. ... ...,... �i ,c wast run at rade suffi•.. _„t to assure complete drain �'. I . f g P g -I'•. All changes in direction shall be made by the appropriate use of fourty-five degree rryes, ' half wyes, long : sp quarter --bends, sixth, eighth, or sixteenth bends, :;:,sitar tees, sid 't opening sanil ,ry s, :,d quarter bends. it sanitary cross shall bu ui Qd on ve:. [cal sta • not less than four Inches in diameter for floor outlet fixtures only. Other double and/oi combination fittings of approved design only shall be used. Short quarter bonds may be used only where one fixture is attached except after approval of the Inspector and in lieu of closet bends, by means of lead or soil studs. Tees, crosses and quarter bends may be used in vent pipes. C. No double hub, tee double tee, or quarter bund with heel inlet shall be used ou soil or waste lines. Permission shall be secured from the Building Inspector for the use of twJn ells. The drilling and tapping of house drains, soil or waste pipes, and the use of .saddle hubs and bends for waste and bent pipe connections, Raymong ferrule:;, drive t'ertitl­,, or, similar ferrules are strictly prohibited. D. Dead ends shall be avoided in the installation of any drainage system. E. Workmanship shall be of a character to secure the results.sought to be obtained in all sections of this Ordinance. I ' F. All plumbing installed by the owner shall comply with the requirements of this Ordinance. When installed by the owner the word "owner" shall.be substituted for the word "plumber" in the interpretation of the provisions of this Ordinance. G. The Durham System of plumbing shall be installed only in buildings of fire -proof con- struction, in buildings of three stories or more, or when fished through finished partitions and floors in old existing buildings, of the proper size and in the manner required by the, plumbing inspector. Wrought iron or steel pipes shall not be used under the ground for s waste, or vent pipes. H. Drainage pipes used for house drain or house sewer, when constructed of tile, or any other material allowing leakage, shall be situated not less than three feet from the wall of any inhabited building and not less than six feet from the property line of adjacent pr- operty occupied or liable to be occupied by another building, when laid parallel with or in the same direction as said wall or property line. If less distance is unavoidable, cast iron soil pipe with caulked lead and oakum joints shall be used. I. No pipes other than cast iron, when used for soil, waste;I or vent, shall be installed underground undera building, or underground for a distance of three feet outside a building: J. When subsoil drains are used, they shall.be. equipped with backwater traps before enter- ing the house drain or house sewer. K. Every dwelling, store, tenement house, factory workshop, auto camp, and construction camp shall be furnished,with a suitable number of water closets or privies, also cesspool or septic tank where no sewer is available; and no cesspool, privy or septic tank shall . hereafter be constructed without a permit first being obtained from the Building Inspector. Said permit shall be issued without charge, and all construction shall be inspected by the Building Inspector. SECTION 7. QUALITY AND WEIGHT OF MATERIALS.'. A. All materials used in any drainage or plumbing system shall be free from defects, which causes unsanitary conditions. Alk B. All cast iron soil pipe and fittings on. private dwellings of not more than two stories may be of standard weight; and on all other classes of buildings, extra heavy shall be used. C. 'hil wrought iron and steel pipes shall be galvanized. The use of conduit, black iron, or black steel pipe is prohibited, except that in vents black pipe may be used. �( lillu"t 1WL WWII hln,,i u.. ....Vi� ' r.a'• E. (e-1) Plain screwed vent fittings shall be of malleable iron, galvanized, or black iron, brass, or copper of standard weit;hC. (e-2) Drainage fittings shall be of cast iron, brass or copper, with smooth interior .. terway, with threads tapped out of solid metal. (e-3) All cast iron and malleable fittings used for water supply distribution shall bt: galvanized. F. Brass ferrules shall be of the best quality red cast brass, not less than 41 inches long and 24,3J, or 4J inches in diameter. G. Soldering nipples shall be of heavy brass or brass pipe, iron pipe size. Vent couplings shall be heavy, ground -faced cast brass. H. Floor flanges for water -closets, slop sinks, and urinals shall be brass not less than 1/8 inch thickness. I. Any materials other than those specified in this Ordinance, which the Building Inspector approves as being equally efficient, may be permitted. SECTION 8. JOINTS AND CONNECTIONS. A. All joints and connections shall be made permanently gas and water tight. B. All joints in vitrified clay or concrete, or between clap pipe, concrete pipe, or metal pipe, shall be made of mortar composed of one part cement and two parts clean, sharp sand, and troweled smooth, or made of sewer seal or hot tar, or compounds equal to Kalkite. No urplus material shall project into the pipe from the joint. All caulked joints shall be firmly packed with oakum or hemp and shall be secured only with molten lead, or equal, not less than one inch deep,well caulked; and no paint,.varnish, or putty will be permitted until after the joint is tested. D. All screw joints shall be of standard thread, and all burrs or cuttings, shall be removed. E. Cast iron, wrought iron, steel, brass, and copper to cast iron. The joints may be either screwed or caulked joints, made in the approved manner. F. Joints in lead pipe or between lead pipe and brass or copper pipes, caulking ferrules, soldering nipples, soldering bushings, ground faced vents, couplings, and traps shall be poured with hot lead. G. Lead to cast iron, steel or wrought iron. The joints shall be made by means of brass caulking ferrule, soldering nipple, or ground faced brass vent couplings. H. Slip jonts shall be permitted only in trap seals, on the inlet and discharge side of the trap and exposed fixture supply pipes. The use of unions is prohibited on waste pipes. I. Only American long screws or gorund joint vent couplings shall be used on vent lines. J. The joints at the roof shall be made tight by means of copper, galvanized iron, or lead, or aluminum flashing. A brass floor flange shall be soldered or poured with hot lead, and the floor connections ` the fixtures bolted to the floor flange. A metal to earthenware, a metal to metal union, a lead gasket, asbestos washer, or equivalent, shall be used to make a gas and water -tight joint. L. Where different sizes of pipes and fittings are to be connected, proper size increasers shall be used. ftttattg .., , • .. , u, r uction of the pipe in the .action of fiuw, which woulu lir ret,:, iluw on the outlet or drain side of any crap, are prohibited. ••,.r: N. Conncectionn of �.,nll hangers, pipe supports, or fixtue settings with iwisouavy, stone,.. concrete, shall be made with expansion bolts, without the use of wooden plugs. SECTION 9. TRAPS AND CLEANOUTS. A. KIND AND SIZE. Traps for lavatories, sinks, and similar fixtures shall be lead or, brass P or S pattern.Traps for bathtubs and laundry trays shall be drum traps and may be lead, brass or cast iron, except that brass, copper or cast iron drum traps may be used only where the Durham System is installed. Shower traps for floor drains may be used for shower baths. The minimum size ( nominal inside diameter) of trap and wasCe branch fora given fixture shall not be less than shown in the following table: j Kind of Fixture Size of Trap Size of Branch Waste Bath Tub 4" X 8" Drum 1}" Bath Shower Stall 4" X 6" or 2" (floor) 1}-2" Bath Sitz 4" X 8" Drum (drain) 1}" Bath Floor 4" X 8" Drum 1}" Dental Cuspidors 4" X 8" Drum 11;" Floor Drains 2" 2" Laundry Trays 4: X 8" Drum 1}" Sink, Kitchen, Residence list 1}" Sink, Hotel, Public 2" 2" Sink, small pantry 1}" 1}" . Soda Fountains, Bar 4: X 10" Drum 1}", Sink, slop with trap combined 2" 2" Sink, slop, ordinary 1py" Jill 1}" •1 Urinal, Lip 1#" 1}" Urinal, trough :i" X 1}" 1}" Urinal Pedestal 3" 3: Urinal, Stall 2: f 1h" Wash Basin 2 " 14" Water Closet -- 4" EXCEPTION: When two bath tubs back to.back are connected to one common waste, the waste shall be increased to two inches in diameter at the point where the connection is made from the trap nearest the soil or waste stack. A. COMBINATION FIXTURE, consisting of a sink and one laundry tray, may be connected to one 4" X 8" drum trap or 1i" P or 5 -Trap connected to each opening of the fixture, with 14" waste in either instance. B.• TRAPS PROHIBITED. No form of trap, which depends for its seal unpon the action of movable parts, concealed interior parts, or made of fittings, shall be used for fixtures. The use of -ball traps is strictly prohibited. C. TRAPS WHERE REQUIRED. Each fixture shall be seperatel)lc trapped by a water seal trap placed not more than twenty four inches from the fixture outlet opening, and when so placed the waste pipe,on the house side of the trap shall be so arranged that it will completly drain. No fixture shall be double trapped. D. WATER SEAL. Each fixture trap shall have a water seal of not less than 14" and not mW than 4". E.' TRAP CLEANOUTS. Each trap, except those in combination with fixtures in which the trap seal is plainly visible and accessible, shall be provided with an accessible brass trap screw of ample size, protected on the sewer'side by the water seal. Drum traps, when made of lead, shall have the trap screw ring wiped to the body of the trap. The accessible trap returned bend, when connected by union joints, will be considered the equivalent of a trap scres. and proLecteu iv G. PIPE CLEANOUTS. On each plumbing system there shall be at least one 4" pipe cleanout, 4•'• placed in the most efficient and accessible location. Other pipe cleanouts shall be placed ;y;.. in all soil and waste lines whereever a horizontal 900 change of direction is made or a hange of direction from the vertical to the horizontal. Pipe cleanouts shall be the nominal size as the pipe which they serve, up to and including four inches in diameter. The cleanout cap or plug shall be of heavy cast brass and be provided with raised nut or recessed.socket for removal. On horizontal lines there shall be an accessible cleanout for each twenty five -`� feet of runl H. UNDERGROUND TRAPS. No traps shall be installed underground, except where there is danger of freezing. I. SAND TRAPS. Sand traps, when installed, should be so designed and placed as to be readily accessible for cleaning, shall have a water seal of not less than six inches, and when placed in a building shall be vented with not less than a two inch pipe. J. FLOOR DRAINS. Floor drains shall connect into a trap so constructed that they can•be readily cleaned, and shall be of a size to efficiently serve the purpose for which they are intended. SECTION 10. PLUMBING FIXTURES A. HOW INSTALLED. All plumbing fixtures shall be.installed in a manner to afford access for cleaning. When practical, all pipes from fixtures shall be run to the wall. B. WATER CLOSET BOWLS. Water closet bowls and traps, with the exception of frost proof ' closets, shall be made in one piece and of such form as to hold a sufficeint quanity of water. when filled to the trap overflow, to prevent foulding surfaces, and shall be provided with an intergal flushing rim constructed so as to flush the entire interior of the bowl. arc. FROST PROOF CLOSETS. Frost proof closets shall be installed only in compartments which have no direct connection with a building used for human habitation. When frost.proof closet are installed in any out building used for other purposes, the same shall be tightly en- closed and accessible from the outside only. Each such closet shall be vented with•a four inch pipe. The bowl shall be flushed by means of a seat attachment to -the valve. D. FIXTURES PROHIBITED. Fixed wooden wash trays or sinks shall not be used for domestic purposes. No new copper lined or sheet metal bath tub shall be installed, and any old fixture of this class taken out shall not be reconnected. E. WATER CLOSET SEATS. All seats of water closets provided for public use shall be of the open front type. F. SHOWER DRAINS AND HOT WATER TANKS. A shower drain shall be considered a fixture. A hot water suplply tank shall be considered a fixture. G. U1ILITY OPENINGS. A utility opening for inspection and repairs shall be provided where the waste, trap, and supplies are concealed on the built in bath tubs and similar fixtures. H.. WATER CLOSET.VENTILATION. No water closet shall be located in a room or appartment which does not contain,a window placed in the external wall,,,or otherwise provided with local ventilation. The minimum size of the local ventiiation opening.shall not be less than fourty eight square inches, and the connecting duct thereto shall have an area of not less than twenty,four inches. When the local ventilation duct is used for more than one room, it shall e increased in size at least one third for each room. Local ventilation pipes shall be perated and distinct, and have no connection whatever. with the other ventilating ducts or pipes:in the building. I. GAS WATER HEATERS. No gas water.heater shall be installed, or if installed, shall be permitted to remain, in any bathroom, bedroom, or toilet room with less than fifteen hundred cubical feet air capacity, unless such room shall be equipped with a permanently open venti- lator�of'not•less than one=.hundred sixty square inches dimension. Every enclosed gas water i, be cuuuccted by a pruput• v.:ut, [AUL. lu:,d Llld„ ,.., . - iuu,.. .. , w �,,.. _ . . . "lA or an effective flue, and such vent pipe shall have no damper or other attachment which will in any way interfere with a free draught. SECTION 1�. SOTL.. WASTE, AND VENT PIPES. .. MATERIAL. All main and branch soil, waste, and vent pipes within a building shall•be of cast iron, galvanized steel, wrought iron, lead, brass, or dopper. B. SOIL AND WASTE STACKS. Every building in which plumbing fixtures are installed shall' have a soil or water stack, or stacks, eatending full size through the roof, and run as + directly as possible. C. SIZE. The following table shall be used to determine the minimum size of soil, waste; and vent pipes required for any one fixture or group of fixtures. 6EW94ORPE KIND OF FIXTURE NUMBER OF FIXTURES SIZE OF BACK VENT.' CLOSETS 1-2 4L' 2" 2-12 411 311 13-50 5" 4" 51-100 6" 5" over 100 8" \ 6" SLOP SINK WITH TRAP COMBINED 1 2" `� 1}" 2 2" 20 3-6 3" . 21ll 7-15 4" 3" SINK, Tubs, luundry trays, 1-2 1}" 1i" ordinary slop sinks, small 3-8 2" 2" signal urinals and 9-18 21ll 2V shower batsh 19-25 3" 3" over 25 4" 4"t �. DRINKING FOUNTAINS, wash 1-4 14" lq" basins, bubbler, refrigerators 5-8 1}" 1}" 9-25 211 . I 211 over 25 3" 3" FLOOR DRAINS 1 2"2"flat 14" vert. 2-4 3112" flat Jill Vert. . 5-8 4113" flat 2" vert. 9-36 6114" flat 3" vert. . SODA FOUNTAINS Bar connections Long trough, Pedestal, combined 1}" to3" 1}" tp trap and porcelain stall urinalsl 1}" ;}" 2-4 2" 2" 5-10 3" 3° 11-25 4" 4" over 25 5" 4" D. CHANGING SOIL AND VENT PIPES. In existing buildings where the soil, waste, and vent pipes are of sheet metal, virtrified tile, concrete, or black iron, not extending undimi- nished through or above the roof, or where traps are unvented; the same shall be changed . to meet the -requirements of this Ordinance whenever a fixture is changed in style or loca- tion or replaced and also whenever connections are made in the house sewer from cesspools' or septic, tanks to the sanitary:sewer'•system. E. PROHIBITED CONNECTIONS. Not -more than one fixture shall be connected to a soil vent, the waste pipe of which shall not exceed one and one half inches in diameter. No water closet, pedestal urinal, or fixture with similar connections, when set on a wood floor;11 shall be connected to soil or house drain by means of a clauked or screwed floor flange.'- F. lange. - F. SOIL AND WASTE PIPE'PROTECTED.' No soil;',waste, or vent pipes shall be run or placed. on the,outside wall -of any building. All roof extensions of soil, waste -or vent stacks shall be run full ;. water trap, - .�__ to the storm water sewer. SECTION 12. BUILDING DRAINS AND HOUSE SEWERS. W INDEPENDENT sr'r M. The plumbing and drainage system of each new building and of �tiL, work installed in an existing building shall be separate from and independent of that of any other building, and every building shall have an independent connection with a public sewer when available. B. OLD HOUSE SEWER. Old house sewers and drains may be used in connection with new build- ings or new plumbin, only when they are found, upon examination or test to conform in all respects to the requirements governing new sewers or drains as prescribed in this Ordinance. C. MATERIAL. The house sewer beginning three feet outside the face of a building founda-, tion wall shall be of cast iron or vitrified sewer or pipe with water tight joints, and shall not be less in size than the drain which they serve'. D. ,HOUSE SEWER IN MADE GROUND. The house sewer, when laid in made or filled'in ground,, shall be of cast iron pipe laid on 12" X 24" slabs or concrete not more than five feet apart. E'. STORM DRAINS. No rain water leaders, area, yard, or court drains shall be connected to a.sewer used for sewage only, exceptwhen expressly authorized in writing by the Bui- lding Inspector; and, when so permitted, they shall discharge into a sand trap before con necting to the same, so located as to be readily accessible for cleaning, and protectected from frost and when necessary with a backwire valve, subject to plans and specifications approved by the Building Inspector. .4 F. RAIN WATER LEADERS. Rain eater leaders,.when placed within a.building, shall be;•cofl- structed of cast iron, glavanized iron, copper, or brass pipe. 'When constructed to the rouse drain or house sewer, they shall be designed and constructed as are the drainage pipes, and shall be effectively trapped before entering the same; PROVIDED, that no glavanized iron pipe shall be used underground. Rain water leaders shall not be used as,soil, waste, or vent pipes; nor shall any soil, waste, or.vent pipes be used as rain water leader or conductors. The use of sheet metal pipes for.'rain water leaders or, , conductors within a building is strictly prohibited. G. OVERFLOW. Overflow,pipes from cisterns, supply tanks, expansion tanks, and drip pans, shall'not be connected directly with any house,drain, house sewer, soil or waste pipes.. H. REFRIGERATOR WASTES. No waste pipe from a refrigerator or ice box or any other receptacle where food is stored shall connect directly with any house drain or_vent pipe. Such waste pipe shall, in all cases, empty into an open fixture which is properly trapped and vented and supplied with water, or maybe discharged into a cellar drain, but the end must be left open to the air. Refrigerator waste pipes shall not be less than one and one- quarter inches for one to three openings, and one and one-half inches for four to twelve openings. Such waste pipes shall be continued not less than full size through the roof, except where such fixtures are located in the basement or first floor. I.,,.LAUNDRIES,,ETC. Waste pipes in dye houses, breweries, bottling works, creameries,. laundries, and similar establishments, where such water is used, may discharge directly onto a non-absorbent floor provided with an adequate number of floor drains; said drains sha4l be connectgd to.the house.sewer with cast iron pipes. J. BOILER BLOW'; -OFFS. The exhaoust, blow=off sediment, or drip pipe from a steam boiler hall not connect directly with any sewer, house drain, soil, or waste pipes. Such pipe hall be connected to a suitable condenser in a manner to meet the requirements of. the Building Inspeotor. E .'INFLAMMABLE WASTE.' All liquid wastes containing gasoline, benzine, naptha, or toher inflammable oils or compounds shall be intercepted before entering the sewer by a suitable catch basin or grease trap properly vented. The vent shall not be smaller in size than the waste pipe which serves the trap. ,t•�weaLlr.. protect.luu, ..,.Ul l...LW,.,.,.uuS Sllull ... .uJJ ....,.. .�vu luUb uUUV�: ,.u.. .. N. TERMINALS. The roof terminal of any stack or vent, if within ten feet of any door, win- dew, scuttle, or air shaft:., shall extend at leant I'ive feet above the same. No stack or,,,;- vent pipe Shall to ivate wider the eaves, cornice, or any other overhang Qf a building. r 1:'. TERMINALS ADJc,.;IING OTNER BUILDINGS. No new building shall be built adjacent to and"• existing building*, in which the windows of the same are located within tcr. feet, of any exist- ', ing vent st;lc6 �1• where thu. vent st:acl: of any new building terminates within ten feet" F.,Af any existing window, unless the owner of the building, with P.he consent. of the owner of of the existing building, shall make such alterations to the existing stack or extensi'on•�' .,' au will meet the requirements of paragraph (h) of this Ordinance J. TRAPS PROTECTED BY VENTS. Every fixture trap shall be protected against siphon§e and back pressure and a circulation of air assured by means of a soil, waste, continous, ` Muck, loop, circuit unit or return vent. �. • K. VENT LIMITS. Trap vents shall be continous where possible. The distance measured along the central line of the waste from the weir of the trap to the vent opening.shall note e,' more than the following distances:` 1}: Trap, 5 inches 17i" Trap, 18 inches 211 Trap, 24 inches I . 3" Trap, 30 inches o•' ' 4" Trap, 36 inches EXCEPTIONS: All water closet bends shall be vented with not less than'a two inch ventl=-^ when over six feet from the soil stack or house drain;'and, when located twenty or* 'ipore"`i1 feet from the soil stack or house drain, the soil pipe shall �e continued undimished'ItWditgh '`.' .the room. No revent is required on toilets.within the required distance of a.vdrtical stack.' for two stories or less. On buildings of three stories.or moie,.they shall be revented.;•" Floor drain vent is permitted up to ten feet from trap. e L. MAIN VENT STACKS. All main vents or vent stacks shall connect full size at their ti to main soil or waste pipe at or below the lowest fixture branch, and shall extend undikim- hed in buildings of less height, they maybe reconnected to the main soil or'wastelstac)f; above the highest fixture. .,:•gyp:. M. VENT PIPE GRADES. All vent and branch vent pipes shall be free from drops or sags, and be so,graded and connected as to drip back to the soil or waste pipe by gravity. Where' " vents connecting to horizontal soil or waste pipes serve•as'crown Ivents, the vent branch shall be taken off the top of the pipe,and raised vertically as.far as possible toward,t4 water line of the fixture before offsetting horizontally or connecting to the branch waste or. soil vent. N. WET VENTS AND BY PASS. No fixture trap shall be wet vent d except those connected to a loop or circuit vent, and all vents shall be constructed sous to eliminate all possi ` bility of their becoming a waste pipe or forming a by pass. 0. CIRCUIT AND LOOP VENTS. A branch,soil or waste pipe to which two or more water closets, urinal stalls, pedestal urinals, shower stalls, or floor drains are connected in series may be vented by a circuit or loop vent which shall be taken off in front of the last fixture:: connection. P. UNIT VENTS. Where fixtures'are'located on opposite sides of a wall or partition oe*'' directly adjacent to each other with the prescribed distances such fixtures may have a common vent. Q. RETURN VENT. Where a building already constructed is more than one story in height" and no vent pipe is available for connection, a fixture may be vented by a return vent-t6, the waste line, provided said vent shall be returned from a point not less than six inches above the rim of said fixture, and connected to the horizontal waste at a distance not'18es 2 than sir, inches from the bertical waste. The size of the waste and vent pipes shall be r,ot less than two inches in diameter. , il-n'PTr.�TT�T.{.:1..-.e^.+T?'p.�••-eferorn•... n•r.w-e.. Win••. .n... .. ....-.r...�..... .-��r•rr..l ..... ..�.... ' L. ACID WASTE. No raw acid waste shall discharge intu any sully Wa: k';, V, urain. Pipes conveying such waste shall be of first-class, salt glazed, vitreous tile pipe and may be connected to the house sewer at the first connection after passing through a ump properly trapped. All joints shall be properly caulked with at least one inch of 1hredded lead and trowled smooth with mortar composed of one part cement and two parts good, clean, sharp sand. All waste pipes carrying acids in suspension shall be of extra heavy lead, lead lined soil pipe, or pure iron pipe. SECTIUN 1.i. REPAIRS, ALTERATIONS, ETC.. A. OLD MATERIALS. All fixtures, fittings, soil waste, vent water pipes removed from an old building, if found to be in good condition and conforming to this Ordinance, may be used again; PROVIDED, the owner of the building in which they are installed gives his consent. B. REMODELING. when an old or defective plumbing fixture is removed to be replaced by a new one, the wastes and vents remodeled, additional fixtures installed or the present ones moved to a new position, a connection made to a sanitary sewer in lieu of a septic tank or cesspool, the remodeled system and all other existing plumbing shall be made to conform to this Ordinance and the Durham System may be used subject to the provisions of Section 12(g) of the Ordinance. SECTION 14. SCHOOLS, THEATERS, AND ASSEMBLY HALLS. A. SCHOOLS. The minimum sanitary equipment for schools, theaters, and assembly halls. shall be as follows: In the superstructure of the building, one drinkings fountain on each floor equipped with slanting jet, one slop sink, one lavatory for each five water closets, or less, one additional lavatory for each additional five water closets or less, one water closet for each fifteen females or less, one water closet for each twenty- -five males or less, and one urunal for each fifteen males or less. Juvenile or short rater closets should be used for primary or grammar schools. Each water closet shall be seperated by means of a stall or partition with at least eight inches between the floor and the bottom of the stall. Buildings more than three stories in height shall be pro vided with toilet rooms in each story and in these shall be installed water closets," lavatories, and urinals in the above rquired ratios in proportion to the number of.persons. to be accommodated in the various stories. B. ASSEMBLY HALLS AND THEATERS. Theaters and assembly halls seating or accommodating three hundred or more persons shall be provided with sanitary equipment as follows: One drinking fountain, available to all, equipped with slanting jet, seperate toilet rooms in connection with auditium, for males and females, in which shall be installed one water closet for each one hundres females, or less, one water closet foe each two hundred males or less and one lavatory for each five water closets or less. SECTION 15. PENALTY. Any person violating any of the provisions of this Ordinance shall, upon conviction, be fined in the sum of not less than One Dollar (1.00) and not exceeding One Hundred Dollars ($400.00) plus cost of prosecution; and, in case of failure to pay said fine ans costs, shall be imprisoned in the Twon Jail until such fine and costs are fully paid at the rate of One Dollar ($ 1.00) per day of imprisonment;PROVIDED, no term of imprisonment for any one offense, shall be for a term longer than three months, PROVIDED FUTHER, 15 days after conviction for the violation of this Ordinance shall be allowed in which to comply with said Ordinance; and each day violation is permitter to continue thereafter shall be considered a seperate offense. 01