ORDINANCE NO. _535�� �ui�oih?ll."Jc,/e�r"r,V/_ AN ORDINANCE PROVIDING FOR THE LICENSING OF PLUMBERS1 PERMITS, INSPECTIONS, GENERAL REGULATIONS COP?CERTTING QUALITY A'11) WEIGHT OF MATERIALS, NND GENERAL REGULATIONS COTSCERNING THE: INSTALLATION OF FIXTURES, DRAINS, ETC. 0 IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF THE'CITY OF SUNDANCE. Section 1. Definitions. The purpose of this Ordinance and certain words and phrases herein are defined as follows: (a) Building: an architectural structure covered by one roof having closed walls with doors and windows therein. (b) Private dwelling: a dwelling house detached from any other build- ing, designed for the use of one family only, and having not to exceed one kitchen and one meter for measuring electric current. (c) Rural and isolated residences: those situated at such distance from a public sewer system that their drainage cannot become tributary thereto. (d) Plumbing system: The water distribution pipes, fixtures, and fixture traps, soil, waste, and vent pipes, house drain and house sewer and storm water drainage, with their appurtenances and cinnection s, all within or adjoining to the building; (e) Plumbing fixtures: receptacles intended to receive and discharge water, liquid, or water -carried waste, into a drainage system with which they are connected. (f) Sanitary plumbing: plumbing that is free from defects in con- struction, conforms in every particular to the provisions of this Ordihance, and.is so designed and installed that it can be kept clean. '(g) Water service pipes: the pipe.from the water main to the build- • g served. (h) Storm water drain: any pipe•or drain which receives any discharge of rain water from buildings or premises; or any seepage or ground water, and conveys the same to any public sewer, building sewer or water course. (1) Water distribution pipes: those which convey water from the service pipe to the plumbing fixture. (j) Vent pipe: any pipe provided to ventilate a building drainage system and •..to.•prevbnt,.trdp siphonage and'. -back pressure. (k) Continuous vent: a pipe extending vertically above the soil or waste branch. (1) Circuit vent: a pipe which vents a series of fixture traps on the same soil or water branch, and which is continued through the roof or reconnected into a vent stack above all fixture trap branches. (m) Unit vent: 'a pipe so arranged that it will vent two traps. (n) Return vent: an inverted emergency vent extended above the water line of the fixture and returned to a point of connection with the horiz- ontal run of the waste pipe from the fixture served on the sewer side of the branch waste from the fixture. (o) Waste vent: That part of a stack which extends above the highest installed fixture trap other than a water closet. (p) Soil vent: a part of a stack which extends above the highest installed water closet. (q) Stack vent: a pipe connecting to the side inlet of a fitting venting a water closet. (r) Wet vent: a pipe used to vent a trap which is also used as a •ste pipe from another trap. (s) Revent (or backvent): that part of a vent pipeline which connects directly with an individual trap, underneath or back of the fixture p and extends either to the main or branch ve�it pipe. (t) Local vent: a pipe through which foul air is removed from a room or the house side of a fixture. (u) Sewage: any liquid waste containing animal or vegetable waste in suspension or solution; may include liquids from laboratories or industrial institutions containing minerals in solution, (v) House sewer: that part of the horizontal piping of a drainage system extending from the house drain to its connection with the main sewer, sewage treatment tank, or leaching well. (w) Sanitary sewer: a drain or sewer constructed to convey organic Obwage from buildings in a septic tank or bacterial treatment tank or other point of disposal, and from which all surface and storm water is excluded. (x) Septic or sewage treatment tank: a water-tight receptacle so constructed as to promote the separation and decomposition of raw sewage which, by bacterial action and sedimentation, effects a process of clar- ification but does not purify the effluent. (y) Leaching well or cesspool: any pit or receptacle having porous walls which permit seepage into the ground. (z) Trap: a fitting or device so constructed as to prevent the pass- age of air or gas through it without materially affecting the flow of sewage or waste water through it. (aa) Trap seal: the vertical distance between the crown weir and the depth of the trap. (bb) The Durham System: the Durham System of plumbing is an installation of waste and soil pipes constructed of brass, copper, wrought iron, steel or cast iron pipes joined together'by means of threaded drainage fittings. (cc) Lead and Spil System: a lead and soil system of pluinbing is an installation of soil and waste pipes constructed of lead and cast iron soil pipes joined together by means of wiped and caulked joints. (dd) Subsoil drain: that part of a drainage system which conveys the subsoil, ground or seepage water from the foot walls or from below the cellar bottom under buildings to the building drain, storm water • drain, or building sewer. (ee) Waste pipe: any pipe which receives the discharge of any fixture, except water closets, and conveys the same to the house drain, soil or waste stacks. When such a pipe does not connect directly with a house drain or soil stack, it is termed a special waste. (ff) Soil pipe: any pipe which conveys the discharge of water closets with-or without the discharge from other fixtures. (gg) House drain: 'any system of horizontal, vertical, or continuous piping which receives the wastes from fixtures, outlets, or traps, directly or through branch pipes. (bb) Branch: the branch of any system of piping is the part of the system which extends horizontally at a slight grade, with or without lateral or vertical extensions or vebtical arms, from the house drain.to receive fixture outlets not directly connected to the house drain. (ii) Stack: a general term for any vertical line of soil, waste, or ve`tjpiping. j) Conductor: 'pipe which carries the storm or rain water from the roof of a building to the building sewer or storm water drain. Down spout is the term which is frequently used to denote the vertical portion of a conductor or roof ladder. (kk) Dead end: a branch leading from a soil, vent, waste, building sewer, which is terminated at a developed distance of two feet or more by means of a cap, plug, or other fitting not used for admitting water to the pipe. (11) Size and length: the given calibre of size of a pipe is Por • a nominal internal diameter. The developed length of a pipe is its -length along the center line of pipe and fittings. (mm) .Wiping a joint: a method of joining together two pieces of metal, to which solder is applied on the joint to a uniform heat suff- icient to obtain a smooth, neatly wiped finish, and having a thickness of solder not less than one fourth inch over the part of the joint where the metal joins. Section 2. Permit Required. With the exception of repairing leaks, cocks, or valves, or cleaning waste or sewer pipes, no person, firm or corporation, or owner shall construct, install, alter or remodel any plumbing or drainage, on or for any building in the Town, without securing �in advance, from the Building Inspector, a permit therefore. Section 3. Permit And Re -ins action Pees. There shall be no charge by the Building Inspec or for permits covering the installation of any plumbing, the laying of any drain or the tapping of a sewer or water line; and there shall be no charge made for any reinspection necessary. Section 4. Inspection. (a) All plumbing and steam fitting installation and connections therewith shall be subject to inspection by the Building Inspector, who shall ascertain any and all. violations of this Ordinance. (b) The equipment, material and labor necessary for inspection and test shall be furnished by the permittee. (c) All work installed shall be tested in the rough, with a water And air test, and all joints shall be made tight. In cases where inspec- tion in the rough is not feasible within eight working hours after request for inspection is received, the Building Inspector shall notify the plumber to proceed with the work. If, upon inspection the character of the work is such as to cause a reasonable doubt as to its tightness, it shall be subject to a test upon the direction of the Building Inspector. (d) If inspection or test bf plumbing reveals improper installation or defects in material, such defective material or imporper installation shall be replaced, altered or repaired not later than a date specified in writing on a tag,or label attached to the system, in a conspicuous,blace by the Building Inspector. (e) Upon the satisfactory completion and final inspection of the plumbing, a tag or label of approval shall be attached to the sy.stem71i1- a conspicuous place, certifying that the plumbing has met the require- ments of the Building Inspector. r (f) No permit or test shall be required for the repair of an old fixture after forcing out stoppage or repairing a leak. Section 5. Separate Ditches for Service Pines. No water or other service pipe shall be placed in the same ditch with a gas service pipe, unless such water or other service pipe be placed not less than twelve inches horizontally from the gas pipe. Section 6. General Reeulations. (a) All horizontal sewer piping shall be run at a uniform grade of not less than one-eighth of an inch per foot, and shall be supported or anchored at intervals of not to exceed ten feet. All stacks shall be supported at their base and all pipes shall be rigidly 'secured. A11 water pipes must run at a grade sufficient to assure complete drainage. (b) All changes in direction shall be made by the appropriate use of forty-five degree wyes, half wyes, long sweep quarter -bends, sixth, eighth, or sixteenth bends sanitary tees side opening sanitary tees and quarter bends. A sanitary cross shali be used on vertical stacks not less than four inches in diameter for floor outlet fixtures only. Other double and/or combination fittings of approved design only shall ae used. Short quarter bends may be used only when one fixture is ttached except after approval of the Inspector and in lieu of closet bends, by means of lead or soil studs. Tees, crosses, and quarter bends may be used in vent pipes. -3-