r1RDINANCE PROVIDING FOR THE LICENSING OF PLUMBERS, PERMITS, INSPECTIONS, GENERAL REGUL- 

ATIONS CONCERNING QUALITY AND WCIGIIT OF MATERIALS, AND GENERAL REGULATIONS CONCERNING THE 

,:..INSTALLATION OF FIXTURES, DRAINS, ETC. 

I, 

'CTION L. DEFINITIONS. 

The purpose of this Ordinance and certain words and phrases herein are defined as follows. 

A. BUILDING: An architectural structure covered by one roof having closed walls with doors 

and windows therein. 

B. PRIVATE DWELLING: A dwelling house detached from any other building, designed for the use 

of one family only and having not to exceed one kitchen and one meter for measuring electric 

current. 

C. RURAL AND ISOLATED RESIDENCES: Those situated at such distance from a public sewer system 

that their drainage cannoL became a tributary thereto. ilc 

D. PLUMBING SYSTEM: The water distribution pipes, fixtures, and fixture traps, soil, waste i. 

and vent pipes, house drain and house sewer and storm water drainage with their appuretenances 4 

and connections all within or adjoining to the building. 

E. PLUMBING FIXTURES: Receptacles intended to receive and discharge water, liquid, or water 

carried waste into a drainage system with which they are connected. 

F. SANITARY PLUMBING: Plumbing that .is free from defects in construction, conforms in every j 

particular to the provisions of this Ordinance and is so designed and installed that it can 

be kept clean. 

WATER SERVICE PIPES: The pipe from the water main to the building served. 

H. STORM WATER DRAIN: Any pipe or drain which receives any discharge of rain water from 

buildings or premises, or any seepage or ground water and conveys the same to any public 

sewer, building sewer, or water course. 

I. WATER DISTRIBUTION PIPES: Those which convey water from the service pipe to the plumbing 

fixture. 

J. .VENT PIPE: Any pipe provided to ventilate a building drainage system and to prevent 

trap siphonage and back pressure. 

K. CONTINUOUS VENT: .A pipe extending vertically above the soil or waste branch. 

L. CIRCUIT VENT: A pipe which vents a series of fixture traps on the same soil or water 

branch and which is continued through the roof or reconnected into a vent static above 

all fixture trap branches. 

M. UNIT VENT: A pipe so arranged that it will vent two traps. 

N. RETURN VENT: An inverted emergency vent extended above the water line of the fixture 

and returned to a point of connection with the horizontal runof the waste pipe from the fix- 

ture served on the sewer side of the branch waste from the fixture. 

0. WASTE VENT: That part of a stach which extends above the highest installed fixture trap 

- nther than a water closet. 

SOIL VENT: A part of a stack which extends above the highest installed water closet. 

Q. STACK VENT: A pipe connecting to the'side inlet of a fitting venting a water closet 

R. WET VENT: A pipe used to vent a trap which is also used as a waste pipe from another 

trap. 

0 

v.. 

:1 .diviauN . trap, undo. acl ue u:. 6, 

vent pipe. 

..T. LOCAL VENT: A pipe Lhrough which foul air is removed from a roan or the hou:;�� side of 

a fixture. 

f `` 

.,U.. SEWAGE: Any ]. _d wa:;t:e containing anim l or vegetable waste in sus��)ension or aolut5 

May include liquids from laboratories or industrial institutions containing minerals. 

in solution. 

V. HOUSE SEWER: That part of a horizontal piping of a drainage system extending from the; 

house drain to its connection with the main sewer, sewage treatment tank or leaching well: 

W. SANITARY SEWER: A drain or sewer constructed to convey organic sewage from buildings. 

in a septic tank or bacterial treatment tank or other point of disposal, and from which'all 

surface and storm water is excluded. vs: - 

SEPTIC 

"- 

SEPTIC OR SEWAGE TREATMENT TANK: A water tight receptacle so constructed as to promote 

the separation and decomposition of raw sewage which, by bacterial action and sedimentation, 

effects a paocess of clarification but does not purify the effluent. C 

Y. LEACHING WELL OR CESSPOOL: Any pit or receptacle having porous walls which permit he= 

epage into the ground. 

Z. TRAP: A fitting or device so constructed as to -prevent the passage of air or gas,the& 

ough it without materially affecting the flow of sewage or wa4te water through it. 

AA. TRAP SEAL: The vertical distance between the crown weir)and the depth of the trap. 

BB. THE DURHAM SYSTEM: The Durham system of plumbing is an installation of waste and'80il 

pipes constructed of brass, copper, wrought iron, steel, or cast iron pipes joined.toget"  

by means of threaded drainage fittings. 

CC. LEAD AND SOIL SYSTEM: A lead and soil system of plumbing is an installation of'soil 

and waste pipes constructed of lead and cast iron soil pipes joined together by means Cf'" " - 

wiped and caulked joints. 

DD. SUBSOIL DRAIN: That part of a drainage system which conveys the subsoil, ground or 

.seepage water from the foot walls or from below the cellar bottom under buildings to the 

building drain, storm water drain, or.building sewer. 

EE. WASTE PIPE. Any pipe which receives the discharge of any fixture, except water clo- 

sets. amd cpmveus tje sa,e tp tje jpise draom. spot. pr waste stacls/ Iden such a pipe 

does not connect directly with a house drain or soil stack itIis termed a special waste. 

FF. SOIL PIPE: Any pipe which conveys the discharge of wateb closets with or without the 

discharge from other fixtures. 

GG. HOUSE DRAIN: any system of horizontal, vertical, or continous piping which receives 

the wastes from fixtures, outlets, or traps directly.or through branch pipes. 

HH. BRANCH: The branch of any system of piping is the part of the system which extends 

horizontally at a slight grade, with or'withdut lateral or vertical extensions or vertical 

arms, from the house drain to receive fixture outlets not directly connected to the" house 

drain. 

II. STACK: A general term for any vertical line of soil, waste'or vent piping. 

JJ. CONDUCTOR: Pipe which carries the storm or rain water from the roof of a building to 

the building sewer or storm water drain. Down spout is the term which is frequently.used. 

to denote the vertical portion of a conductor or roof ladder. 

KK. DEAD END: A branch leading from a soil, vent waste building sewer, which is terminated 

"i used for admitting water to the pipe. 

LL. SIZE AND LENGT11. The given calibre of size of a pipe is for a nominal internal,diameter. 

,-The developed length of a pipe is its length along the center line of pipe and fittings,, 

*I. WIPING A JOINT: A method of joining together two pieces of metal, to which solder iu 

t; applied on the jodnt to a uniforhp heat sufficient to obtain a smooth, neatly wiped finish, 

over the part of the joint where the metal joins. 

SECTION 2. PERMIT REQUIRED. 

With the exception of repairing leaks, cocks, or valves, or cleaning waste or sewer pipes,,no 

person firm or corporation, or owner shall construct, install alter, or remodel any plumbipz 

or drainage on or for any building in the Town without securing in advance from'the Build#ng 

Inspector a permit therefore. 

SECTION 3. PERMIT AND REINSPECTION FEES. 

There shall be no charges by the Building Inspector for permits covering the installation'of 

any plumbin, the laying of any drain, or the tapping of a sewer or water line; and there.. 

shall be no charge made for any reinspection necessary. 

SECTION 4 INSPECTION. . 

A. All plumbing and steam fitting installation and connections therewith shall be subject 

to inspection by the Building Inspector who shall ascertain any and'all violations of this 

Ordinance. 

B. The equipment, material and labor necessary for inspection and test shall be furnished, 

by the permittee. 

All work installed shall be tested in the rough with a water and air test, and all joints 

shall be made tight. In cases where inspection in,the rough is not feasible within eight 

working hours after request for inspection is received the Building Inspector shall no jfy, 

the plumber to proceed with the work. If, upon inspection.the" character of the work.is.such 

as to cause a reasonable doubt as to its tightness it shall be subject to a test,upon.the 

direction of the Building Inspector. 

D. If inspection or test of plumbing reveals improper installation or defects in material, 

such defective material or improper installation shall be'replaced, altered, or repaired, 

not later than a date specified in writing on a tag or label attached to the system iri.a 

conspicuous place by the Building Inspector. 

E. Upon the satisfactory completion and final inspection of the plumbin, a tag or label ,of 

approval shall be attached to the system in a conspicuous place certifying that the plumbing 

has met the requirements of the Building Inspector. 

F. No permit or test shall be required for the repair of an old fixture after forcing out 

stoppage or repairing a leak. . ' 

SECTION 5. SEPERATE DITCHES FOR SERVICE PIPES. 

No water or other service pipe shall be placed in -the same ditch with a gas service pipe 

unless such water or other service pipe be placed not less than twelve inches horizontally 

from the gas pipe. 

TION 6. GENERAL REGULATIONS 

A.' All horizontal sewer piping shall be run at a uniform grade of not less than one-eighth, 

of an inch per foot, and shall be supported or anchored at intervals of not to exceed ten 

feet. All stacks shall be supported at their base and all pipes shall be rigidly secured. 

,cks shall u�� .;V ulr ��."  . ....i ��tt,cs .,/ ::����. ... ...,... 

��i ,c wast run at rade suffi" .. _ t to assure complete drain 

��'. I . f g P g 

-I'" . All changes in direction shall be made by the appropriate use of fourty-five degree rryes, 

' half wyes, long : sp quarter --bends, sixth, eighth, or sixteenth bends, :;:,sitar tees, sid 

't opening sanil ,ry s, :,d quarter bends. it sanitary cross shall bu ui Qd on ve:. [cal sta 

"  not less than four Inches in diameter for floor outlet fixtures only. Other double and/oi 

combination fittings of approved design only shall be used. Short quarter bonds may be used 

only where one fixture is attached except after approval of the Inspector and in lieu of 

closet bends, by means of lead or soil studs. Tees, crosses and quarter bends may be used 

in vent pipes. 

C. No double hub, tee double tee, or quarter bund with heel inlet shall be used ou soil or 

waste lines. Permission shall be secured from the Building Inspector for the use of twJn 

ells. The drilling and tapping of house drains, soil or waste pipes, and the use of .saddle 

hubs and bends for waste and bent pipe connections, Raymong ferrule:;, drive t'ertitl�,, or, 

similar ferrules are strictly prohibited. 

D. Dead ends shall be avoided in the installation of any drainage system. 

E. Workmanship shall be of a character to secure the results.sought to be obtained in all 

sections of this Ordinance. 

I ' 

F. All plumbing installed by the owner shall comply with the requirements of this Ordinance. 

When installed by the owner the word "owner" shall.be substituted for the word "plumber" 

in the interpretation of the provisions of this Ordinance. 

G. The Durham System of plumbing shall be installed only in buildings of fire -proof con- 

struction, in buildings of three stories or more, or when fished through finished partitions 

and floors in old existing buildings, of the proper size and in the manner required by the, 

plumbing inspector. Wrought iron or steel pipes shall not be used under the ground for s 

waste, or vent pipes. 

H. Drainage pipes used for house drain or house sewer, when constructed of tile, or any 

other material allowing leakage, shall be situated not less than three feet from the wall 

of any inhabited building and not less than six feet from the property line of adjacent pr- 

operty occupied or liable to be occupied by another building, when laid parallel with or in 

the same direction as said wall or property line. If less distance is unavoidable, cast 

iron soil pipe with caulked lead and oakum joints shall be used. 

I. No pipes other than cast iron, when used for soil, waste;I or vent, shall be installed 

underground undera building, or underground for a distance of three feet outside a building: 

J. When subsoil drains are used, they shall.be. equipped with backwater traps before enter- 

 
Last Page